Danfoss does, however, recommend strict compliance with refrigerant manufacturer instructions and procedures.© Copyright 2020, Cooling Post Ltd - All Rights Reserved | It is the rest of the system that will determine if R134A can be used, most likely not unless it is modified. These are R407A – a blend of 40% R134a, 40% R125 and 20% R32 – with a GWP of 1990. 3.

1-Screw Chillers air cooled using R134a versus R407c 2-Package Units using R 22 versus R 134a 3-Package Units using R 22 versus R 407c 4-DX Package Units using R 134a versus R 407c Which of the options with the matching Refrigerent apply best for high Ambient temperatures + … On the same date a ban will be imposed on hermetically sealed commercial refrigerators and freezers containing HFCs with the same high GWPs. R407C is a zeotropic mixture consisting of 23% R32, 25% R125 and 52% R134a. Several A2L refrigerants (e.g. R134a and R407C These refrigerants are used mainly for air conditioning and substitution of R22 in many applications.

In new systems, what are the best refrigerant options for commercial medium and low temperature equipment/installations?

an expansion valve - is approved for.Refrigerants not approved for a product might not be compatible with some of the raw material e.g. Depending on the regulatory limits for the quantity of fluid, the cooling capacity required and the types of compressor used, we decided to use these 4 gases: R290A, R449A, R452A and R404A.

What are the best replacements for R404A / R507 that I can use in medium temperature applications, now and in the future? R417A is the zero ODP replacement for R22 suitable for new equipment and as a drop-in replacement for existing systems. One in particular concerns us the most. Refrigerant Transition Center We can see A2L-R454A, R455C and R1234yf emerging for new systems. Until now there have been three main replacements for R404A.

In addition, our range of scroll compressors are also compatible with these refrigerants for both medium and low temperature applications but with liquid injection.All material Danfoss uses are compatible with the refrigerants the product - e.g. As of 2012, the heating, ventilating and air conditioning (HVAC) industry is in the process of … The best choice will depend on the type of application.-> For more information about the impact on system performance and components, access the It depends entirely on the application. The other is R407F which favours slightly more R32 to R125 in a blend of 40% R134a, 30% R125 and 30% R32.

Over the last few years, our governments have been trying to reduce the environmental footprint by enacting various regulations. In mid-size installations such as cold rooms, milk tanks, display cabinets, and blast freezers, there are several options which relate to Article 12 of the EU F-gas regulations. The glide requires a minor adjustment to the expansion device.Some suppliers also recommend that you overhaul your refrigeration system during the retrofit operation including the filter drier and seals.A slightly more recent introduction to the market, R407F has been adopted by many supermarkets across Europe using R404A systems due to R407F’s improved capacity and energy efficiency.An area of concern raised initially by compressor manufacturers, is in the application of these alternative refrigerants at very low temperatures (below -35° C). It is complicated to choose one refrigerant fluid more than another for all refrigeration applications because none of the actors are ready for this change:We chose to split our approach according to the field of use of the equipment.We eliminated the R134A due to a lack of choice of compressors in the power range needed for our applications and an uncertain economic return.Depending on the regulatory limits for the quantity of fluid, the cooling capacity required and the types of compressor used, we decided to use these 4 gases: R290A, R449A, R452A and R404A.The R290A is the most durable solution for small powers; that is, the storage cabinets.

However, in 2017, supply problems with the R404A had quite an impact.The 37% decrease imposed for 2018 is therefore about 1/3 less than the 2016 or 2017 gas consumption. 407C are Polyol ester lubricants. It has a similar cooling capacity to R404A and improved energy efficiency. Also, it is essential to seek further information from your refrigerant supplier and compressor manufacturer(s) before performing a retrofit.Promoted as an ideal retrofit solution for many existing R404A systems, R407A has been freely available on the market for over twenty years. We have lots of guys ticketed for R134a. What impacts does a new refrigerant have on system performance? 3. Please only use components which are approved for your specific refrigerant. I prefer to suggest clients for chilled water coil systems, in these cases, in order to prevent too much condensate or risk of freezing on the coil surface. These offer lower GWPs.